Intro: GCK low voltage withdrawable switchgear is widely used in power plants, metallurgical steel rolling, petrochemical industry, light industry and textiles, ports, buildings, hotels and other places as AC three-phase four-wire or five-wire system, voltage 380V, 660V, frequency 50Hz, rated The current is used for power distribution and motor centralized control in power supply systems of 5000A and below.


Product Detail

Product Tags

GCK Design feature

1.GCK1 and REGCl are assemble type combined structure. The basic skeleton is assembled by adopting special bar steel.

2.Cabinet skeleton, component dimension and starter size change according to basic modulus E=25mm.

3.In MCC project,parts in cabinet are divided into five zones (compartment): horizontal bus bar zone, vertical bus bar zone, function unit zone, cable compartment, and neutral earthing bus bar zone.Each zone is separated mutually for circuit's normal running and effectively preventing fault expansion.

4.As all structures of framework are connected and fixed by bolts,so it avoids the welding distortion and stress, and upgrades the precision.

5.Strong general performance, well applicability and high standardization degree for components.

6.Draw-out and insert of function unit (drawer) is lever operation, which is easy and reliable with rolling bearing.

Use of conditions:

1. Operating conditions: indoor
2. Altitude: It: 2000m
3. The earthquake intensity is not more than 8 degrees
4, upper limit of ambient air temperature: +40℃
5.Upper limit of average temperature for 24 hours: +35℃
6. the lower limit of ambient air temperature :-5℃
7. the relative humidity of the surrounding environment at +40℃ is 50%
8. no fire, explosion danger, serious pollution and enough to corrode metaland damage the insulation of gas and other bad places
9.No violent vibration, jolting place

Technical Parameters:

No.

Content

Unit

Value

1

Rated Operating Voltage

V

380/690

2

Rated Insulation Voltage

V

660/1000

3

Rated Frequency

Hz

50

4

Main Bus-Bar Rated Current

A

<3150

Rated Short-time Withstand Current(ls)

kA

<80

Rated Peak Withstand Current

kA

<143

5

Distribution Bus Rated Current

A

<1000

Distribution Bus(Is) Rated Short-time Withstand Current(ls)

kA

<50

Rated Peak Withstand Current

kA

<105

6

  Aux. circuit Frequency Withstand Voltage in Imin

kV

2

7

  Rated Impulse Withstand Voltage

kV

8

8

  Protect Degree

IP

P54 to IP54

9

  Electrical Clearance

mm

>10

10

  Creepage Distance

mm

>12.5

11

  Over-voltage Level

-

III/IV

12

  Class of Pollution

-

3